Placing ramps

Place a straight, turning or curved ramp from the Build tray, then adjust it in Parameters.

With Move or Rotate armed, you can pick a ramp on any storey in the same way as another object.

  1. Choose Ramp beside Stairs in Build.
  2. Set the width, gradient and rise in Parameters before placing it.
  3. Click on the active storey to place the ramp. Select it to edit the same parameters.

Under Dimensions, Base offset lifts the start above its storey and Top offset adjusts the arrival height. A new ramp starts with a rise of 450 mm, about 5.4 m of run at 1:12, unless you set Total rise or a top level. Clear Total rise to let the levels and offsets determine the rise. A placed ramp's Level row moves it to another storey while keeping its offsets.

Click the top of a mass, or a point snapped to it, to start the ramp at that height. Base offset adds to the caught height; the preview and placed ramp use the same start.

Slope and length

Gradient preset offers 1:12, 1:15, 1:20, 1:60 and Custom. Custom keeps the current slope; type its denominator in Gradient 1:N. Shallow gradients such as 1:25 and 1:60 can describe graded paths. Total rise overrides the height between levels; clear it to follow the levels again. Length mode lets Run length drive the slope, with the gradient shown as a ratio and percentage.

Landings and turns

Under Landings, choose Add landing, then set its position along the sloped run and its length. Choose Left or Right and 90° for an L, or 180° for a switchback. For a curved ramp, choose a curve direction and radius; the sweep controls set its run length. The same controls remain available after placement.

Handrails and a bare body

In Railing, choose a handrail on the left, right or both sides. Look offers Classic (posts and a handrail), Traditional, Glass + timber, Frameless glass and Utility, the same looks a stair has, and the rows beneath it set the posts, handrail, spindles, bottom rail and glass panes. Spindles, panes, posts and rails follow the slope, across landings and turns. The Railing section folds like a stair row and ends with swatches for the railing and, on a glass look, the glass, each picked from the Library and returned to default with Auto. Set the guard height, and the upstand sides and height, separately. Choose None for both railing and upstand to leave a fully bare ramp body. The body can be solid or a slab of the thickness you set.

The panel reports gradients steeper than 1:12, landings shorter than 1.2 m, tight curves and turns outside a landing. Each warning describes the drawn geometry. Plan views show the ramp outline, slope arrow and gradient; on a floor the ramp arrives at or passes through, the slab of that floor hides the ramp under it, as it does a stair. Sections and elevations use the same body and guards as the model. CAD exports put ramps on A-FLOR-RAMP.