Placing stairs
Set the stair first, then place it with one click.
Bring the stair close to a wall to seat it flush against a face: the outer face of its handrail and posts meets the wall, or the stringer when it has neither. Moving the stair uses the same outside, and so does dragging a stair's width grip: on a straight stair's first flight in plan only the side you drag moves and the far side stays where it is, a later flight widens evenly about the flight before it so no other flight shifts, and a curved stair's grip (plan and 3D) moves its outer edge; in every case the dragged side's outside catches wall faces, edges and points. When a footprint corner or edge midpoint catches an existing point, a circle marks the point and its word reads Corner, Endpoint or Midpoint, in plan and 3D. Continuing past that point keeps the stair moving forward when its alignment changes to another face. Click to place the preview. See Snapping and inference.
To detail a stair, open a section through it and draw a callout around the part you need. Draw lines and regions over the stair in the callout; this drafting belongs to that view. Dimensions can follow individual tread nosings and landing edges when you change the stair in Parameters. If an edit removes a referenced tread, the dimension reads UNLINKED. Change the stair's size in Parameters; typing a dimension figure does not resize it.
Copying or duplicating a stair also copies its paired railings and pairs them with the new stair. This applies when you select only the stair, and when you include its railings in the selection. Each copied stair gets a distinct name, such as Staircase 1 copy, so Pair with stair lists each stair separately. One undo removes the stair copy and its copied railings together.
To change a placed stair's rise or riser height, select it and open Dimensions in its panel: set Steps, or type a Riser and the step count that lands nearest follows. Rise reads out from the levels the stair joins.
Ramp parameters
Select a ramp and open Parameters. In Gradient mode, the Gradient preset menu offers 1:12, 1:15, 1:20, 1:60 and Custom. The Gradient 1:N field is always available below the menu. Choosing Custom keeps the current slope; enter your own denominator in the field. Dragging uses 1:5 to 1:100; typed denominators can range from 0.25 to 2000. Total rise sets the height in metres; clear it to follow the levels again. At a fixed gradient, changing the rise changes the run. In Length mode, set Run length instead; the gradient reads as a ratio and percentage.
Under Landings, click Add landing to insert a 1.2 m landing halfway along the sloped run. Edit its position along the slope and its length in metres, or remove it. Landing positions exclude the lengths of other landings and are capped at the sloped run. Landing length has a 0.1 m minimum. The gradient presets, height, run length and landings can be adjusted to form a custom ramp.
Dimensions and drawing tools snap to the ends, midpoints and lines of tread nosings, to riser corners and to landing edges, in plan and 3D. Pick two nosings to set out a run by its going.
Open tread removes the risers and keeps the two side strings, using the Closed or Cut setting under Railing. Choose None there to remove the strings. On curved and spiral stairs the handrail follows the curve as one continuous length, with newel posts at the ends. Each spindle meets the handrail underside and, with a bottom rail, stands flush on that rail; with no bottom rail it stands on its tread. Section drawings show its simple outline.
To repeat a stair through a stairwell, select it and click Copy to level in its action menu. Pick several destinations, then Paste Aligned to Selected Levels. Each copy keeps the same span in storeys and its offsets, with its rise following the new levels. A different rise recalculates the default steps; the Check and automatic floor openings follow. A message names a destination with too few levels above it, while the others go ahead. One undo removes all the copies. See Working with levels.
A stair's Face finishes show in plan on the flights seen from above: the treads of a flight below the cut plane, and the lower part of a flight the plane crosses, up to the break line. A curved or spiral stair takes it the same way, over the sweep up to its break line. The part above the plane keeps its cut drawing.
A stair's body in plan takes the same ground a floor does, so the grid does not show through it, on the light canvas and on the dark. On a floor the stair arrives at or passes through, that floor's slab hides the steps under it, and the rails and posts under it: the flight draws only where the floor has an opening, or where no floor covers it, except for the newel posts and the stretch of handrail that rise above the floor where the flight arrives, which still draw, whether the stair stands loose or inside a group. The travel line is cropped with the treads, so no line runs under solid floor, the UP or DN label stands on the first tread you can see through the opening, and drawn from the floor above the arrow runs on to the very top tread. Clicking solid floor over a hidden flight picks the floor. A floor below the stair, a floor you have hidden, and a demolished floor cover nothing. In a printed or exported drawing the stair body is paper white, as on screen, so a tinted room does not show through the flight; a face finish draws over the white, and in DWG or DXF the white is a hatch in paper colour.

- Click Stairs on the Build toolbar.
- Set the stair in Parameters.
- Click where it should go. R and T turn it in 45 degree steps before you click.
Click on the top of a mass, or on a point you've snapped to on one, and the flight starts at that height.
With magnetic snapping on, the stair seats itself as you move it: a flank or an end lies flush on a wall face or a slab edge, its corners and end midpoints take the ends and midpoints of what is there, and its centre line slides onto a point such as a wall's midpoint. A curved or spiral stair seats by its curve: the outer edge of the sweep touches a straight wall or edge at a single point and never crosses it, and its ends, middle and centre take the points around it. The same seating works on every storey. The ghost shows exactly where it lands.
The type sits open at the top; the other sections (Dimensions, Constraints, Check, Railing, Opening, Annotation, Construction, Details) fold, the way a wall's do. Check opens by itself when the stair breaks a limit.
Parameters holds the whole stair before anything is placed. Choose the type (Straight, Dog-leg, L-shape, Curved or Spiral), the width, and the number of steps, with the riser and the tread (going) that go with them. A flight-based stair also takes its construction (Solid, Slab or Open tread), and a dog-leg or L-shape its turn and how many treads sit either side of the landing. A curved or spiral stair takes its rise, inner radius and sweep, and a spiral its centre column, step supports and top landing. A spiral's top landing has no depth of its own to set: it runs from the last tread to the edge of the floor opening, wherever the opening ends. The railing (which sides, height, spindles or glass, spacing, handrail radius) and the opening cut in the floor above are set there too. The opening is cut wherever the stair stands within 2 m of the underside of the floor above, for every stair type (a curved or spiral stair opens as a curved strip over its treads), and it allows for the real depth of the floor above: a floor with a type uses its full build-up, and a plain floor allows at least 250 mm, so a thicker floor opens a little more.
The stair under your cursor redraws as you change each setting, and it lands the way it shows. The riser is the rise divided by the steps, so typing a riser picks the step count that lands nearest to it.
A dog-leg stair has Flight gap in Dimensions, before and after placement. It starts at 150 mm and can be set from 50 mm upwards. Increasing it separates the parallel flights and widens the landing, with the floor opening and its landing guard following the stair.
A stair has two widths in Dimensions, before and after placement. Width is the overall construction width, the one stored with the stair. Clear width is what a person can use: the width between the handrails, or between a handrail and the wall, less the strings. It follows the railing, the handrail size and the strings, so it moves when you change them. Type a clear width and the overall width is set so the clear width lands on it. The rule check reports each flight's clear width as a figure and does not judge it against a minimum.
A new stair starts as a UK domestic stair: 900 wide on a 250 going, with the number of steps that brings the riser closest to 200 and never past 220. Until you set the steps yourself the count follows the floor to floor height, so the same stair armed on a taller level gains risers.
Constraints sets where the stair starts and stops: Base offset, Top level and Top offset, with the base Level itself under Type. It climbs to the level above unless you pick another under Top level, which reads Unconnected when there is no level above, and which lets one stair run through two storeys or more; Base offset and Top offset lift or drop either end from its level, and the rise follows. A straight stair of more than 16 risers is laid with a landing. Turn off Landings where needed to keep it as one flight.
Annotation sets what the plan writes beside the arrow. UP / DN labels turns the words off on every level the stair is drawn on (on by default, and saved with the stair), Travel arrow turns the arrow off on every level (its line, its head and a curved stair's start dot; switch both off and the plan says nothing), and Arrowhead chooses the solid head or an open chevron, two thin lines from the two ends of the tread to the travel line, filling the tread width. Upward travel, the default, labels the stair UP on every level it is drawn on, with the arrow pointing the way you climb. Show down labels the top level DN and draws its travel line with no head, because the arrowhead never points down the flight, and a level the stair passes through reads both UP and DN. Numbers writes a number on every tread (or every riser) of every flight in one go, from the number you give in Start at, the count running on across a landing; only the treads below the plan cut are numbered. Drag the grip beside the UP or DN label, or any tread number, to put it where you want it; the numbers move together, and Reset label positions in the stair panel puts them back. A placed stair has the same settings in its own panel.
To clear the stair of its words, select it: a grip sits at the UP or DN text at every drawing scale, and another appears on the stair's mark tag. Drag a grip to move that one by hand. The label and the tag keep their offset from the stair, so they travel and turn with it, a tag moved off the stair gets a leader back to where it stood, and one drag is one undo step. Double-click a grip to put the label or the tag back in its place. Plan tread lines meet the sides of the stair and stop at handrail and post outlines. The run line starts on the bottom tread, which is drawn once. PDF, DXF and DWG use the same visible linework.
Details shapes the front edge of every tread. Nosing length is how far a tread overhangs the riser below it (0 to 60 mm; an open stair starts at 25 mm, a solid or slab stair at none), and Nosing profile is Square, Rounded or Chamfered. Choosing Rounded or Chamfered with no length set supplies a 25 mm nosing. Setting the length explicitly to zero disables shaping until you increase it. Nosing thickness is how deep the nosing is at its front (10 to 60 mm; 30 mm on a solid or slab stair, never more than half a riser, and the tread's own thickness on an open stair). Rounded is a bullnose: the front of the nosing is radiused outward, both top and bottom, at the nosing length, and Nosing radius sets the radius (a full round on the thickness until you set it; never more than half the thickness or the nosing length). Chamfered cuts the top front corner by Chamfer size. Every profile keeps its front at the nosing length, so plan and section show the same edge, and the section draws the profile. Lip hangs the tread's front edge down over an open riser, so it is offered on open stairs only (a solid or slab stair has a riser there already); a lip you set stays stored when you switch construction and comes back on switching to open. Nosing strips inlays a contrast band into each nosing, over its front and across the top, standing 1 mm proud and following the profile, with its own Strip width on the tread and its own paint slot, Nosing strips, so the paint bucket reaches it. Going stays measured nosing to nosing, so a projection keeps the same going. Riser strip width draws a band on the riser below each nosing, including the landing edge, using the same paint as the tread strip. It is disabled on open stairs because there is no riser. The band fits the available riser face. Sections and their exports show its real shape; plan keeps the outer nosing line. A placed stair has the same Details section in its own panel.
A placed stair has a Mark at the top of its form, such as 00.S01: the next free number on its level, given when the stair is placed and kept when other stairs are added, deleted or reordered. Type your own to replace it (it is set in capitals, up to 16 characters), or clear the field to fall back to the stair's order on the level. The stair schedule's Mark column shows it, and the plan draws it as a tag on the stair, in the same bubble a door or window mark uses; it hides with the Type marks check, the same one that hides door and window marks. The tag is drawn on the stair's own floor only: on the floor the stair arrives at, and on any floor it passes through, you see the stair and its UP or DN label but not the tag.
Construction records what the stair is made of: the Structure (Timber, Steel, In-situ concrete or Precast concrete), the Handrail (Timber, Steel, Stainless steel or Aluminium), the Infill (Timber spindles, Steel spindles, Toughened glass, Laminated glass, Panel, Mesh or None) and the Tread finish (Timber, Carpet, Stone, Tile or None). A new stair starts as Timber; every other choice starts as Not specified, which stores nothing. These choices set the stair's materials in 3D and in section, taken from the material library. The Structure sets the starting material of the strings: timber for a timber stair, metal for the rest. A timber, steel or stainless Handrail gives the handrail and newels that material, timber or steel spindles give the spindles theirs, and each Tread finish (Timber, Carpet, Stone, Tile) puts its own material on the treads. Aluminium, both glasses, panel and mesh each take their own material from the library. An Infill of None draws no infill at all, in plan or in 3D. Handrail, Balusters and Infill are three separate paint slots; the strings stay part of the stair itself. A material you paint on the handrail, balusters, infill, strings or treads always wins, and Corb reads and writes all four choices. A placed stair has the same section in its own panel.
Check shows pitch and twice the rise plus the going (2R + G), with plain numeric warnings for unusual stair dimensions. Rise is compared with 150 to 220 mm, going with 220 to 300 mm and pitch with 42 degrees. The usual 2R + G range is 550 to 700 mm. A flight over 16 risers, or a run over 36 risers without a turn, is flagged as unusually long. Clear width is reported as a number. Curved stairs measure going on the centre line below 1 m width, and 270 mm in from each side from 1 m width; a narrow tread end below 50 mm is flagged. A new curved or spiral stair starts with geometry suited to the default dimensions. On a curved stair, type Going and the sweep or inner radius follows, according to Hold; type Riser and the step count follows. A spiral reports its riser height. The controls keep their full range, and the stair is drawn with the dimensions you choose. Corb can report these measurements and geometric warnings.
A landing can be split into steps. In Advanced, open the landing and set Landing split in Dimensions: Straight divides it into two or more treads across the way out, and on an L-shape stair Winders fans the treads from the inside corner of the turn. Treads sets how many. The stair keeps its total rise and every riser stays the same height, and plan, 3D, sections and DXF export all show the steps. Tread and riser numbers run on through the landing, the stair schedule counts its risers, and the stair check counts them in the run. Winders start a little way out from the inside corner so no tread comes to a point, keeping at least 50 mm of going at the narrow end (the check flags a landing too small for that), and the first step carries the same nosing as any tread.
A stair that cuts an opening in the floor above can guard it. Open Opening on the placed stair and click Add landing guard: a railing paired with the stair is laid round every edge of the opening except the one the stair arrives at, and ends on the stair's top newel. It follows the opening when you change the stair, and one undo takes it away.
Railing builds the balustrade part by part. Choose which sides are guarded, then the strings down the sides of each flight (closed, which hides the tread ends; cut, which is notched under each tread; or none), the newel posts (with Newel size, Newel height, the distance the top of a post stands above the top of the handrail, and Post section: Square, Round tube or Flat bar; a square post stands 80 mm above the rail and a round or flat one stops at it until you set a height), the handrail, and what fills the space beneath it: spindles, glass or nothing. Glass is one raking pane per bay, parallel to the pitch of the flight. The handrail of a curved or spiral stair is one smooth rail swept round the curve from the post at the foot to the post at the head, climbing the pitch of the treads, and the glass is curved panes, one per bay, bending with the stair; a spiral with an integrated landing carries the rail and the glass on level round the landing at the height of the floor above, to the edge of the opening where you step off onto the floor, and a level guard stands on the floor along the opening's other straight edge, where it drops onto the treads below. Turning the handrail off takes that guard's rail away with it. Spindles stand on the treads and reach the underside of the rail wherever it is. Look sets all four at once: Traditional, Glass + timber, Frameless glass (glass alone fixed to the side of the stair) or Utility, a plain steel guard: slim 48 mm round tube posts with no cap, a round 42 mm tube handrail and 12 mm round bars with a default 100 mm clear gap, in the balustrade's metal finish. Utility also sets those sizes, and choosing another Look puts the ordinary sizes back. Handrail profile makes the handrail Rectangular, a flat section wider than it is deep, or Round, a cylinder; it shows while the handrail is on and applies to every length of handrail on the stair, curved and spiral stairs included. Handrail width and Handrail height size a Rectangular handrail (62 by 44 mm until you change them, each set on its own) and Handrail diameter a Round one (44 mm). With glass infill the section also offers Pane width (the longest a pane may be, 1.2 m until you change it; a longer bay splits into equal panes, on a curved or spiral stair measured along the curve), Pane gap (10 mm between neighbouring panes) and Glass thickness (12 mm), and the section drawing shows the thickness you set. When two flights meet with no landing between them, the open ends at the turn are guarded, whichever sides carry a railing: a level guard runs along the head of the lower flight where there is a drop, and along the part of the upper flight's foot that the lower flight does not sit under, with the same handrail, base rail and spindles or glass as the flights, never over the treads, and a newel at each free end when newels are on; a flight that ends on its own is finished with a post at its end.
To take a run of balustrade away, for the side that stands against a wall, set the guard to Both, then either select the stair, click the run in plan or in 3D and press Delete, or right-click the run (the stair need not be selected first) and choose Remove balustrade here. The whole run, post to post, goes and the stair stays, with a post at each end where the guard now stops; Undo brings it back. Removed runs are listed under Railing with Restore beside each and Restore all, and changing which sides are guarded keeps them. A side removed along its whole length no longer takes guard width out of the clear width. A railing paired with the stair does not move when a run is removed.
In plan the handrail is a band as wide as the handrail itself (61.6 mm for the default rail, whatever width or diameter you set), two parallel lines down each guarded side, with a square at each end and turning post. The lines stop at each post rather than running through it, a break line across the flight ends on the band's inside face, and a curved or swept railing draws the same band. It is solid below the cut plane and dashed above it, and spindles, glass panes and the base rail are left to the 3D view. Where the cut plane crosses a flight the plan draws a diagonal break line from the inside face of one handrail to the inside face of the other, or out to the flight's edge on a side with no rail. A stair that ends at the next floor gets a single break line, and a stair that continues up gets a double one: two parallel diagonals with a clear 175 mm gap between them, so both flights read. Where one stair arrives from below and another goes on up over it, the floor they meet on draws the double break across the run: the flight going on up draws its lower treads below the lower line, with UP at its foot, and beyond the upper line the arriving flight draws its top treads and says nothing, no travel line, no DN and no arrowhead, until Show down is chosen, when it reads DN with a plain line. The stair reads UP by default; DN only appears under Show down. The going-on flight's travel line runs through the break, its arrow pointing up the page, and nothing is drawn in the gap. The stair underneath, with nothing arriving, keeps a single break. The travel arrow stops a small fixed gap short of the break line. On a curved or spiral stair a travel line also runs down the middle of the run, from the first tread to the top, solid below the cut and dashed above it, the break line lies along a tread line instead of slanting across the treads, and the treads below the cut are drawn in the full projection pen. A stair that climbs through more than one storey is drawn on every level it passes and on the level it arrives at, where it reads UP or, with the down label chosen, DN.
Stairs do not offer Create Parts or Divide Parts. Use the stair and railing parameters to change their build. Existing stair parts remain in the model, and Restore Excluded brings back excluded runs or landings.
Parameters keeps what you set for the next stair. Reset to default clears it. Escape cancels.
Select a placed stair and Parameters shows the same form, so width, steps, tread, the split either side of a landing and the levels are changed on the stair as a whole. Its base Level sits under Type and the rest under Constraints, a raised slab on the same level can be picked as its top, and Position moves and turns it. Flights holds Add flight and Add landing, and Advanced lists each flight and landing: click one to open its own fields in place and make it active for its canvas grips, while the stair stays selected. Collapse the row, deselect the stair or change the view mode to clear that target. An individually locked flight has inert row controls and no live grips, even when the stair is unlocked.